ENVIRONMENTAL
Working temperature
0 to +60 deg C
Functional temperature
-25 to +70 deg C
Storage temperature
-55 to +85 deg C
Temperature coefficient
0.02% per deg C (100 ppm / °C)
Relative humidity
95% non condensing
Class of climate
HSE complying with DIN 40040
-3 complying with
VDE/VDI 3540
INSULATION
Test Voltage
4kV RMS 50Hz 1min.
between
Input / Case
/ Auxiliary / Output
Impulse test EMC
5kV transient complying
with IEC 801 /
EN55020
HF interference
test EHF 2.5kV 1MHz complying
with IEC 255-4
Protection class
II complying with IEC 348
BS
4753 / DIN 57411 / VDE
0411
APPLIED STANDARDS
General IEC 688
/ BS 6253 / VDE/
VDI 2192
Safety BS EN61010
DIN 57411 / VDE
0411
ANSI C37
Surge withstand
IEC 801 / EN 55020
ANSI C37-90a
Radio screening
RFI degree N complies with
VDE 0875
EMC Emissions EN50081-2
Immunity EN50082-1
APPROVALS
cU.L. Approval
File No E157034
|