SELECTION
GUIDE
M100-VS1 Suppressed zero
voltage auxiliary powered
M100-VX1 1 ph. aux. powered
ave. sensing RMS calibrated
M100-VX33 ph. aux. powered
ave. sensing RMS
TYPICAL APPLICATIONS
The M100-VS1 is a self
powered voltage transducer. The suppression allows the transducer to accurately
measure a voltage system over a narrow band either side of a nominal voltage.
The range can be between ± 10% to ± 30% which can be specified when ordering.
Typical application is to display the voltage on an analogue meter with
an expanded scale. This allows the user to read small changes in the voltage
in a single or 3 phase system. The output could also be fed to a computer
that could then control the voltage of the system, to ensure that it stays
within the narrow band.
The M100-VX1 and VX3
are essentially the same as the M100-VA1 and VA3, but they have auxiliaries
which allow the working range to be 0-125% rather than 10-125%.
Used where the average
sensing of voltage is required from 0 to 125% of the nominal voltage.
ORDERING INFORMATION
Product Code Input Un
Output Aux Freq. Option
M100-VS1 110V ± 15% 20mA
- 50Hz
OPTIONS
1.
Non standard inputs / outputs only as far as technically
acceptable.
2. A.C. Auxiliary in
range 57.7 to 450 volts
3. Calibration at nominal
Hz 35.....450Hz
4. Calibration at temperature
other than 23°C
|
|
|
TECHNICAL
SPECIFICATION
INPUT
Rated value Un 57.8
<100 / 110 <600 V
Power consumption <
1 VA (VX1, VX3)
<1.5 VA (VS1)
Working range 0-125%
Un (VX1, VX3)
10-30% Un (VS1)
Rated Frequency 50 /
60 / 400 Hz
Frequency influence
0.005 % / Hz
Overload continuous
1.5 x Un
Overload for 1 sec.
2 x Un
OUTPUT
Rated value mA 0-1 /
5 / 10 / 20mA (VX1, VX3)
Rated value mA 1/5/10/20
& 4-20mA (VS1)
Rated value volts 0-5
/ 10 V (VX1, VX3)
Rated value volts 0-5
/ 10 V & 1-5 V (VS1)
ADJUSTMENT
Zero No adjustment (VX1,
VX3)
Zero ± 2% (VS1)
Span ± 10% (VX1, VX3,
VS1)
AUXILIARY
A.C. Voltage 115 / 230
/ 400 V
(± 25% / 45-65Hz / <2
VA)
calibrated
D.C. Voltage 24 / 48
/ 110 V (± 20%
galvanically isolated
/ < 3 W)
Note M100-VS1 is self
powered
WEIGHT & CASE SIZE
M100-VS1,VX1 Approx.
0.4 kg. 55mm case
M100-VX3Approx. 0.7
kg.
|
|