SELECTION
GUIDE
M100-FE1 Frequency range
0-10kHz
TYPICAL APPLICATIONS
The M100-FE1 measure the
frequency of the input signal and provides a DC output that is directly
proportional to the input frequency. The FE1 can accept frequency or pulse
inputs over a wide range. The frequency range is 0-10kHz, with the minimum
span being 100Hz and maximum span 10kHz.
The M100-FE1 can be used
in a wide variety of application such as speed measurement taking its
input signal from a proximity sensor, flow measurement etc.
Isolation of 1.5kV is
provided between the input and the output signal allowing the output to
be fed to conventional analogue meters, digital meters, PLC and computer
systems.
ORDERING INFORMATION
Product code I/P Hz I/P
Un Output Aux Freq. Options
M100-FE1 600Hz 10V 4-20mA
230V 50Hz
OPTIONS
1. Non standard inputs
/ outputs only as far as technically
acceptable.
2. A.C. Auxiliary in
range 57.7 to 450 volts
3. Calibration at temperature
other than 23°C
|
|
|
TECHNICAL
INFORMATION
INPUT
Input range Hz 0-100Hz
minimum span
voltage range 0- volts
Input range Hz 0-10kHz
maximum span
Voltage range 0- volts
Working range ± 125%
Hz
Overload continuous 1.5
x Un
OUTPUT
Rated value mA 0-1/5/10/20
& 4-20mA
Load resistance 12/2.4/1.2/0.6
kOhm
Rated value volts 0-5
/ 10 & 1-5 V
ADJUSTMENT
Zero ± 2%
Span ± 10%
AUXILIARY
A.C. Voltage 115 / 230
/ 400 V (± 25% / 45-65
Hz / < 2VA)
D.C. Voltage 24 / 48
/ 110 V (± 20% /
galvanically isolated
/ <3W)
WEIGHT & CASE SIZE Approx.
0.4 kg. 55mm case
|
|
|