SELECTION
GUIDE
M100-TJ1 Type J thermocouple
M100-TK1 Type K thermocouple
TYPICAL APPLICATIONS
The M100-TJ1 and TK1
measure the millivolt drop of J and K type thermocouples respectively.
Thermocouples are made
from two dissimilar metals and as the temperature rises, the mV across
the thermocouple increases. The millivolts developed corresponds to the
change in temperature, thermocouple manufacturers provide tables
showing temperature versus
voltage drop. The M100 TJ1 / TK1 measures this voltage change and converts
it to an output signal that corresponds to the temperature being monitored.
The output from the M100-TJ1/ TK1 is not linearised Thermocouple temperature
measurement is used in a variety of applications, including monitoring
of temperature of furnaces etc.
The M100 thermocouple
transducer is provided with automatic cold junction temperature compensation
over the
range 0-50 °C. Also provided
is thermocouple break protection should the thermocouple leads break,
the output from the transducer will go to its maximum or minimum output
value, depending on which option is chosen at time of ordering.
ORDERING INFORMATION
Product Code:Temperature:Output:Auxiliary:Frequency
M100-TK1 0-500°C 1 mA
120V 60Hz Up scale
OPTIONS
1. Non standard inputs
/ outputs only as far as technically acceptable.
2. A.C. Auxiliary in
range 57.7 to 450 volts
3. Calibration at temperature
other than 23°C
4. Up or down scale break
protection
|
|
|
TECHNICAL
SPECIFICATION
INPUT
Type J Fe/Const. Min.
range 0-185°C (min. span 10mV) Max range 0-870 °C (max. span 50mV)
Type K NiCr/NiAl Min.
range 0-245 °C (min. span 10mV) Max. range 0-1230 °C (max. span 50mV)
Impedance - >10kOhm
Thermocouple Break protection
Upscale or down scale
optional
Cold junction compensation
- Automatic over the range 0-50 °C
Overload - 10 x input
continuous
OUTPUT
Rated value mA - 0-1/5/10/20
& 4-20mA
Load resistance - 12/2.4/1.2/0.6
kOhm
Rated value volts - 0-5
/ 10 & 1-5 V
ADJUSTMENT
Zero - ±2%
Span - ±10%
AUXILIARY
A.C. Voltage - 115 /
230 / 400 V (± 25% / 45-65 Hz / < 2VA)
D.C. Voltage - 24 / 48
/ 110 V (± 20% / galvanically isolated / <3W)
WEIGHT & CASE SIZE Approx.
0.4 kg. case 55mm
NOTE
No isolation is provided
between input and output
|
|