| RELAY
GENERAL SPECIFICATIONS |
|
|
|
|
ENVIRONMENTAL
Working temperature,
0 to +60 deg C
Functional temperature,
-25 to + 70 deg C
Storage temperature,
-40 to +85 deg C
Temperature Coefficient,
0.03% per deg C (300ppm/degC)
Relative humidity, 95%
non condensing
Class of climate, HSE
complying with DIN -3 complying with VDE/VDI 3540
INSULATION
Test voltage, 4kV RMS
50Hz 1min between Input / Case /Auxiliary
Impulse test, EMC 5kV
transient complying with IEC801 / EN55020
HF interference test,
EHF 2.5kv 1MHz complying with IEC 255-4
Protection class, II
complying with IEC348
APPLIED STANDARDS
General, IEC 144/ BS
5420/ VDE/ VDI 0435/ IEC 947/ EN60947
Safety, BS EN 61010 DIN
57411 / VDE 0411 ANSI C37
Surge withstand, IEC
801 / EN 55020 ANSI C37-90a
Radio screening, RFI
degree N complies with VDEO87S
EMC Emissions EN50081-2
Immunity EN50082-1
|
|
|
|
|
|
RELAY
OUTPUT
Relay type, dual pole
change over
Material, Silver / Cadmium
Contact resistance, 200mOhm
max, typically <5Om Ohm
Rating AC, 250V 5A non
resistive 12OOVA
Rating DC, 125V 1A resistive
120 watts
Electrical life, 1 x
10e6 at above load
Mechanical life, 5 x
10e6
Operating time approx.
7ms (20ms max)
Dielectric strength
Between coil and contacts,
5kV RMS 1min
Between open contacts,
1kV RMS Imin
Between adjacent contacts,
1kV RMS imin
Insulation resistance,
1000M Ohm at 500V DC
Operating temperature,
-30 to + 75 deg C
Approval UL and CSA recognised
ENCLOSURE
Fixing Snap on to DIN
rail 35 x7.5 mm
complies with DIN-EN
50022 BS 5584
Mounting Any position.
Enclosure Code Case IP50,
terminals IP30
Complies with IEC 529
BS 5490 DIN 40050
Material Complying with
UL94 VO
APPROVALS
U.L. Approval File No
E157034
|
|
 |
 |
 |
 |
 |