INPUT..........TYPE............RANGE
AC VOLTS.. M300-VAD..
0.....600V
DC VOLTS.. M300-VD1 ...± 50/60/75/100/150mV
DC VOLTS.. M300-VD2 ...± 50mV
..... 1999mV
DC VOLTS ..M300-VD3 ...± 2V.....199.9V
DC VOLTS ..M300-VD4 ...± 200V....600V
AC AMPS ..M300-AAD.. 1 or
5 AC (0.2 TO 10A)
DC AMPS ..M300-AD1 ...±
1 / 5 / 10 / 20mA
DC AMPS ..M300-AD2 ...± 100uA.....
199.9uA
DC AMPS ..M300-AD3... ± 20mA......10A
DC AMPS ..M300-AD4 ...4/20mA
FREQUENCY M300-HZD
35Hz..... 199.9Hz
PERFORMANCE
IMPENDANCE :-
M300-VAD 10k Ohm/V
M300-VD1/2 >100k Ohm/V
M300-VD3/4 10k Ohm/V
BURDEN
M300-AAD <
2VA
M300-AD1/2/3/4 20mV
OVERLOAD
Current 4 x continuous
25 x 1 second
Voltage 1.5 x
continuous
4 x 1 second
Accuracy ± 0.05%
of reading ± 1 digit
Resolution 0.05%
Linearity ± 1 digit roll
over error ± 2 digits
Conversion Dual slope
integration
CMR AC 50dB 50 to 60
Hz
DC 25 1k Ohm source
unbalanced.
Normal
mode rejection 25dB 50 to 60Hz
ENVIRONMENTAL
Working
Temperature 0 to +60 deg C
Function Temperature
- 25 to +70 deg C
Storage Temperature -55
to +85 deg C
Temperature Coefficient
0.01% per deg C
Relative Humidity 0-95%
non condensing
Warm up time 1 min.
Shock 30G in 3 planes |
|
|
INSULATION
Test Voltage 4kV RMS
50Hz 1 min
AUXILIARY
AC Voltage 115 or 230
Volts (± 25%)
45 to 65 Hz. Burden
< 2VA
DC Voltage 24
/ 48 / 110 Volts (± 20%)
Galvanic isolation.
Burden < 3W
DISPLAY
Digits 1999 Full scale
Size 14.2mm (o.56")
7 segment red
Decimal point Internally
selectable
Overrange indication
Display "1" or "-1"
Update response time
< 1 second
Polarity Automatic
with (-) indicating
negative inputs
ENCLOSURE
Standard DIN case 96 x 48 x
94 mm
Panel mount Via retaining
side brackets and screws
Panelcutout 92 + 0.8mm
x 45 + 0.8mm
Material Black Polycarbonate
complying with
UL 94 VO
Terminals Screw terminal
for 2 x 0.5-3.5mm
Enclosure code IP54
NEMA 12
Weight 0.4kg
GENERAL & SAFETY
INSTRUCTIONS
All units built and tested for
safety, accuracy, quality and
reliability. Units
are delivered fully calibrated, however
adjustments to "ZERO"
and "SPAN" can be made by removing
the appropriate covers
on the rear of the instrument.
These products must
be installed by a qualified engineer.
VOLTAGE dangerous
to human life may be present at some of
the terminals of this
unit. Exercise extreme caution during
installation.
|
|