PPH Divisor Setting
Read or Set the desired divisor for the Energy Counters.

Divide by:- 1000, 100, 10, 1, 0.1, 0.01, 0.001 can be used.

The following is dependent on the number of pph (5000 max)
A value of 1 puts the meter into A.h mode.
A value of 1000 divides by 1000
A value of 0.001 multiplies by 1000

Sample Coding
Slave Address = 1
A.h divisor update: Register Address 20h
Writing To 4X Registers - code 16 (10 hex)
Value to write = 10

Message Packet To SLAVE
01 10 00 20 00 02 04 41 20 00 00 E4 41
N.B. Value 41 20 00 00 = 10

Response Packet From SLAVE
01 10 00 0A 00 02 61 CA